Industrietechnik
Humidity and temperature transmitter for room mounting, IP30
Designed for accurate measurement of temperature and relative humidity in indoor air environments. Perfect for HVAC systems, it is the ideal solution for residential, commercial, and industrial applications where accuracy and performance are a priority.
Articles
(24 st)-
TTUARH + °C- Sensor Interface
- 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Output humidity
- 0-10 V
-
TTUA-PT100RH + PT100, 100 Ohm (0°C)- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-PT1000RH + PT1000, 1000 Ohm (0°C)- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-NTC1.8RH + NTC 1.8, 1800 Ohm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-NTC2.2RH + NTC 2.2, 2252 Ohm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-NTC10-01RH + NTC 10, 10 kOhm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-NTC10-02RH + NTC 10, 10 kOhm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-NTC10-03RH + NTC 10, 10 kOhm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-NTC20RH + NTC 20, 20 kOhm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-NI1000-01RH + Ni1000, 1000 Ohm/0°C- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-NI1000-02RH + Ni1000, 1000 Ohm/0°C- Sensor Interface
- Passive, 0-10 V
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-DRH + °C- Sensor Interface
- 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Output humidity
- 0-10 V
-
TTUA-MRH + C°- Sensor Interface
- Modbus RTU
- Display
- No
- Measuring range, temp
- 0…50 °C
- Output temperature
- Modbus
- Output humidity
- Modbus
-
TTUA-D-PT100RH + PT100, 100 Ohm/0°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-PT1000RH + PT1000, 1000 Ohm (0°C)- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-NTC1.8RH + NTC 1.8, 1800 Ohm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-NTC2.2RH + NTC 2.2, 2252 Ohm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-NTC10-01RH + NTC 10, 10 kOhm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-NTC10-02RH + NTC 10, 10 kOhm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-NTC10-03RH + NTC 10, 10 kOhm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-NTC20RH + NTC 20, 20 kOhm/25°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-NI1000-01RH + Ni1000, 1000 Ohm/0°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-NI1000-02RH + Ni1000, 1000 Ohm/0°C- Sensor Interface
- Passive, 0-10 V
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output humidity
- 0-10 V
-
TTUA-D-MRH + °C- Sensor Interface
- Modbus RTU
- Display
- Yes
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- Modbus
- Output humidity
- Modbus
Specifications
| Power Supply | 24VAC/DC (22...26 V AC 50Hz / 15...35 V DC), 2.0 VA |
|---|---|
| Appliance class | Class III |
| Protection class | IP30 |
| Ambient humidity (non-condensing) | 10…90 % RH |
| Ambient temperature | 0…50 °C |
| Storage temperature | -25…60 °C |
| Mounting | Room |
| Dimensions, external (WxHxD) | 100x85x30 mm |
| Accuracy, temperature | ± 0.4 K, ±0.3 K, ±0.5 K, ±0.2 K, ±0.25 K, 0.2 K |
| Accuracy, temperature 1 | ± °K @ 0... °C |
| Measuring range, humidity | 0…100 % RH |
| Sensor element, humidity | Capacitive |
| Accuracy, humidity | ±3 % RH at 20°C |
| Terminal type | Screw Terminal |
| Terminal wire size | 0.75 mm² |
| Material, housing | Polycarbonate (PC) |
| Colour, housing | Signal white RAL 9003 |
| Power consumption | < 1 W |
| Transformer power | ≥ 2 VA |
| Power supply | 24 Vac ±10% / 15...35 Vdc |
Software & documentation
Product sheets
Instructions
Other documentation