Industrietechnik

Duct humidity/temperature transmitter

The duct-type TUTC transmitter series is designed for accurate temperature and humidity measurement. These transmitters deliver reliable performance and easy integration for building management and HVAC applications.

Articles

(20 st)
  • TUTC0111 - Regin
    TUTC0111
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    0…50 °C
    Output temperature
    0-10 V
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC0121 - Regin
    TUTC0121
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -30…50 °C
    Output temperature
    0-10 V
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC0131 - Regin
    TUTC0131
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    0…100 °C
    Output temperature
    0-10 V
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC0212 - Regin
    TUTC0212
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    0…50 °C
    Output temperature
    4-20 mA (2 wire)
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    2
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC
  • TUTC0222 - Regin
    TUTC0222
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    -30…50 °C
    Output temperature
    4-20 mA (2 wire)
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    1.5
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC
  • TUTC0232 - Regin
    TUTC0232
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    0…100 °C
    Output temperature
    4-20 mA (2 wire)
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    2
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC
  • TUTC1101 - Regin
    TUTC1101
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC1102 - Regin
    TUTC1102
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    0.6
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC
  • TUTC1103 - Regin
    TUTC1103
    Dimensions, external (WxHxD)
    75x103x266 mm
    Tube length
    23 cm
    Tube diameter
    12 mm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -20…50 °C
    Output temperature
    NTC 10K-02 B3435
    Measuring range, humidity
    0…100 % RH
    Output humidity
    0-5 V
    Colour, cover
    White
    Colour, base
    Grey
    Power consumption
    < 1 W
  • TUTC1301 - Regin
    TUTC1301
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC1302 - Regin
    TUTC1302
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    0.6
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC
  • TUTC1401 - Regin
    TUTC1401
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC1402 - Regin
    TUTC1402
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    0.2
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC
  • TUTC1501 - Regin
    TUTC1501
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC1502 - Regin
    TUTC1502
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    0.2
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC
  • TUTC1601 - Regin
    TUTC1601
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC1602 - Regin
    TUTC1602
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    0.6
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC
  • TUTC1701 - Regin
    TUTC1701
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC2101 - Regin
    TUTC2101
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 0...10v
    >1000 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    0-10 V
    Colour, cover
    White
    Colour, base
    Grey
  • TUTC2102 - Regin
    TUTC2102
    Tube length
    23 cm
    Insertion length
    60…230 mm
    Analogue output load impedance 4...20mA
    With power supply 11...17 V DC: RL <50 Ω
    Measuring range, temp
    -20…50 °C
    Output humidity
    4-20 mA (2 wire)
    Hysteresis, humidity
    ± 3% RH
    Accuracy, gas in air
    0.3
    Colour, cover
    White
    Colour, base
    White
    Power supply (4...20 mA)
    Max 30 V DC, Min 11+(0.02xRL) V DC

Specifications

Specifications for Duct humidity/temperature transmitter
Appliance class Class III
Protection class IP65
Ambient humidity (non-condensing) 10…95 % RH
Ambient temperature -5…50 °C
Storage temperature -20…70 °C
Mounting Duct
Dimensions, external (WxHxD) 75x103x266 mm, 75x10x266 mm
Weight, incl. packaging 0.26 kg, 0.17 kg
Tube diameter 12 mm
Accuracy, temperature 1 K, 1.5 K, 2 K, 0.6 K, NTC 10K-02 B3435 K, NTC 1K8 B3416 K, 0.2 K, NTC 10K-01 B3977 K, NTC 10K-03 B3695 K, NTC 20K B4262 K, 0.3 K, PT100 Class B K
Measuring range, humidity 0…100 % RH
Accuracy, humidity ± 3% RH
Cable gland M16x1,5
Terminal type Screw Terminal
Terminal wire size 0.75 mm²
Material, housing Polycarbonate
Material, cover Polycarbonate
Material sealing Grey
Power consumption < 1 W
Power supply 18...24 Vac / 18...35 Vdc, Min (11-(0,02xRL)) Vdc, max 30 Vdc

Accessories