Industrietechnik
Duct humidity/temperature transmitter
The duct-type TUTC transmitter series is designed for accurate temperature and humidity measurement. These transmitters deliver reliable performance and easy integration for building management and HVAC applications.
Articles
(20 st)-
TUTC0111- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC0121- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -30…50 °C
- Output temperature
- 0-10 V
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC0131- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- 0…100 °C
- Output temperature
- 0-10 V
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC0212- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- 0…50 °C
- Output temperature
- 4-20 mA (2 wire)
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
-
TUTC0222- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -30…50 °C
- Output temperature
- 4-20 mA (2 wire)
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 1.5
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
-
TUTC0232- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- 0…100 °C
- Output temperature
- 4-20 mA (2 wire)
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
-
TUTC1101- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC1102- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
-
TUTC1103- Dimensions, external (WxHxD)
- 75x103x266 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 10K-02 B3435
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-5 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTC1301- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC1302- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
-
TUTC1401- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC1402- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
-
TUTC1501- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC1502- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
-
TUTC1601- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC1602- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
-
TUTC1701- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC2101- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTC2102- Tube length
- 23 cm
- Insertion length
- 60…230 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.3
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
Specifications
| Appliance class | Class III |
|---|---|
| Protection class | IP65 |
| Ambient humidity (non-condensing) | 10…95 % RH |
| Ambient temperature | -5…50 °C |
| Storage temperature | -20…70 °C |
| Mounting | Duct |
| Dimensions, external (WxHxD) | 75x103x266 mm, 75x10x266 mm |
| Weight, incl. packaging | 0.26 kg, 0.17 kg |
| Tube diameter | 12 mm |
| Accuracy, temperature | 1 K, 1.5 K, 2 K, 0.6 K, NTC 10K-02 B3435 K, NTC 1K8 B3416 K, 0.2 K, NTC 10K-01 B3977 K, NTC 10K-03 B3695 K, NTC 20K B4262 K, 0.3 K, PT100 Class B K |
| Measuring range, humidity | 0…100 % RH |
| Accuracy, humidity | ± 3% RH |
| Cable gland | M16x1,5 |
| Terminal type | Screw Terminal |
| Terminal wire size | 0.75 mm² |
| Material, housing | Polycarbonate |
| Material, cover | Polycarbonate |
| Material sealing | Grey |
| Power consumption | < 1 W |
| Power supply | 18...24 Vac / 18...35 Vdc, Min (11-(0,02xRL)) Vdc, max 30 Vdc |
Software & documentation
Product sheet
Instructions
Other documentation
Accessories