Industrietechnik

Humidity and temperature transmitter for room mounting, IP30

Designed for accurate measurement of temperature and relative humidity in indoor air environments. Perfect for HVAC systems, it is the ideal solution for residential, commercial, and industrial applications where accuracy and performance are a priority.

Articles

(24 st)
  • TTUA - Regin
    TTUA
    RH + °C
    Measuring range, temp
    0…50 °C
    Output temperature
    0-10 V
    Output humidity
    0-10 V
  • TTUA-PT100 - Regin
    TTUA-PT100
    RH + PT100, 100 Ohm (0°C)
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-PT1000 - Regin
    TTUA-PT1000
    RH + PT1000, 1000 Ohm (0°C)
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-NTC1.8 - Regin
    TTUA-NTC1.8
    RH + NTC 1.8, 1800 Ohm/25°C
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-NTC2.2 - Regin
    TTUA-NTC2.2
    RH + NTC 2.2, 2252 Ohm/25°C
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-NTC10-01 - Regin
    TTUA-NTC10-01
    RH + NTC 10, 10 kOhm/25°C
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-NTC10-02 - Regin
    TTUA-NTC10-02
    RH + NTC 10, 10 kOhm/25°C
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-NTC10-03 - Regin
    TTUA-NTC10-03
    RH + NTC 10, 10 kOhm/25°C
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-NTC20 - Regin
    TTUA-NTC20
    RH + NTC 20, 20 kOhm/25°C
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-NI1000-01 - Regin
    TTUA-NI1000-01
    RH + Ni1000, 1000 Ohm/0°C
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-NI1000-02 - Regin
    TTUA-NI1000-02
    RH + Ni1000, 1000 Ohm/0°C
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D - Regin
    TTUA-D
    RH + °C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output temperature
    0-10 V
    Output humidity
    0-10 V
  • TTUA-M - Regin
    TTUA-M
    RH + C°
    Measuring range, temp
    0…50 °C
    Output temperature
    Modbus
    Output humidity
    Modbus
  • TTUA-D-PT100 - Regin
    TTUA-D-PT100
    RH + PT100, 100 Ohm/0°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-PT1000 - Regin
    TTUA-D-PT1000
    RH + PT1000, 1000 Ohm (0°C)
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-NTC1.8 - Regin
    TTUA-D-NTC1.8
    RH + NTC 1.8, 1800 Ohm/25°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-NTC2.2 - Regin
    TTUA-D-NTC2.2
    RH + NTC 2.2, 2252 Ohm/25°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-NTC10-01 - Regin
    TTUA-D-NTC10-01
    RH + NTC 10, 10 kOhm/25°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-NTC10-02 - Regin
    TTUA-D-NTC10-02
    RH + NTC 10, 10 kOhm/25°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-NTC10-03 - Regin
    TTUA-D-NTC10-03
    RH + NTC 10, 10 kOhm/25°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-NTC20 - Regin
    TTUA-D-NTC20
    RH + NTC 20, 20 kOhm/25°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-NI1000-01 - Regin
    TTUA-D-NI1000-01
    RH + Ni1000, 1000 Ohm/0°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-NI1000-02 - Regin
    TTUA-D-NI1000-02
    RH + Ni1000, 1000 Ohm/0°C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output humidity
    0-10 V
  • TTUA-D-M - Regin
    TTUA-D-M
    RH + °C
    Display
    Yes
    Display type
    LCD
    Measuring range, temp
    0…50 °C
    Output temperature
    Modbus
    Output humidity
    Modbus

Specifications

Specifications for Humidity and temperature transmitter for room mounting, IP30
Mounting Room
Power Supply 24VAC/DC (22...26 V AC 50Hz / 15...35 V DC), 2.0 VA
Appliance class Class III
Protection class IP30
Ambient humidity (non-condensing) 10…90 % RH
Ambient temperature 0…50 °C
Storage temperature -25…60 °C
Mounting Room
Dimensions, external (WxHxD) 100x85x30 mm
Accuracy, temperature ± 0.4 K, ±0.3 K, ±0.5 K, ±0.2 K, ±0.25 K, 0.2 K
Accuracy, temperature 1 ± °K @ 0... °C
Measuring range, humidity 0…100 % RH
Terminal type Screw Terminal
Terminal wire size 0.75 mm²
Material, housing Polycarbonate (PC)
Colour, housing Signal white RAL 9003
Power consumption < 1 W
Transformer power ≥ 2 VA
Power supply 24 Vac ±10% / 15...35 Vdc