Industrietechnik
Pressure transmitter for liquids and gases
Pressure transmitter for measurement of liquids and gases.
Articles
(14 st)-
TPGL1- Power Supply
- 24 Vac ±15% / 12...33 Vdc
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...100 kPa
- Max. overload pressure
- 300 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 0-10 V
- Current consumption
- < 7 mA
-
TPGL1-420- Power Supply
- 7...33 Vdc
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...100 kPa
- Max. overload pressure
- 300 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 4-20 mA
- Current consumption
- < 23 mA
-
TPGL2.5- Power Supply
- 24 Vac ±15% / 12...33 Vdc
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...250 kPa
- Max. overload pressure
- 750 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 0-10 V
- Current consumption
- < 7 mA
-
TPGL2.5-420- Power Supply
- 7...33 Vdc
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...250 kPa
- Max. overload pressure
- 750 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 4-20 mA
- Current consumption
- < 23 mA
-
TPGL6- Power Supply
- 24 Vac ±15% / 12...33 Vdc
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...600 kPa
- Max. overload pressure
- 1500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 0-10 V
- Current consumption
- < 7 mA
-
TPGL6-420- Power Supply
- 7...33 Vdc
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...600 kPa
- Max. overload pressure
- 1500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 4-20 mA
- Current consumption
- < 23 mA
-
TPGL10- Power Supply
- 24 Vac ±15% / 12...33 Vdc
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...1000 kPa
- Max. overload pressure
- 2500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 0-10 V
- Current consumption
- < 7 mA
-
TPGL10-420- Power Supply
- 7...33 Vdc
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...1000 kPa
- Max. overload pressure
- 2500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 4-20 mA
- Current consumption
- < 23 mA
-
TPGL16- Power Supply
- 24 Vac ±15% / 12...33 Vdc
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...1600 kPa
- Max. overload pressure
- 4000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 0-10 V
- Current consumption
- < 7 mA
-
TPGL16-420- Power Supply
- 7...33 Vdc
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...1600 kPa
- Max. overload pressure
- 4000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 4-20 mA
- Current consumption
- < 23 mA
-
TPGL25- Power Supply
- 24 Vac ±15% / 12...33 Vdc
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...2500 kPa
- Max. overload pressure
- 6250 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 0-10 V
- Current consumption
- < 7 mA
-
TPGL25-420- Power Supply
- 7...33 Vdc
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...2500 kPa
- Max. overload pressure
- 6250 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 4-20 mA
- Current consumption
- < 23 mA
-
TPGL40- Power Supply
- 24 Vac ±15% / 12...33 Vdc
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...4000 kPa
- Max. overload pressure
- 10000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 0-10 V
- Current consumption
- < 7 mA
-
TPGL40-420- Power Supply
- 7...33 Vdc
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...4000 kPa
- Max. overload pressure
- 10000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Output signal
- 4-20 mA
- Current consumption
- < 23 mA
Specifications
| Protection class | IP67 |
|---|---|
| Ambient temperature | -30…85 °C |
| Storage temperature | -50…100 °C |
| Bulb length | 47.5 mm |
| Bulb diameter | 24 mm |
| Weight, incl. packaging | 0.9 kg |
| Media | Liquids and gases |
| (Well/Pressure) connection | G 1/4 " |
| Cable | 1.5 m three-wire, 1.5 m two-wire |
| Pressure connection | Outside thread |
| Dynamic response time | < 2 ms, 1 ms typically |
| Media temperature | -15…+125°C |
| Material sealing | FPM |
Software & documentation
Product sheet
Other documentation