Industrietechnik

Immersion thermostat, IP65

High quality immersion thermostats for use in cooling, heating and ventilation systems.

Articles

(12 st)
  • DBTV-1 - Regin
    DBTV-1
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    60 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    -30...30 °C
    Hysteresis, temperature
    2...20 K
    Reset function
    Automatic
    Setpoint adjustment
    External
    Dimensions, external (WxHxD)
    70*72*108 mm
  • DBTV-7U - Regin
    DBTV-7U
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    75 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    0...60 °C
    Hysteresis, temperature
    2...20 K
    Reset function
    Automatic
    Setpoint adjustment
    Internal
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-8 - Regin
    DBTV-8
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    75 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    0...60 °C
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Setpoint adjustment
    External
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-11 - Regin
    DBTV-11
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    140 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    50...120 °C
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Setpoint adjustment
    External
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-16 - Regin
    DBTV-16
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    100 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    20...90 °C
    Hysteresis, temperature
    2...20 K
    Reset function
    Automatic
    Setpoint adjustment
    External
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-17 - Regin
    DBTV-17
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    100 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    20...90 °C
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Setpoint adjustment
    External
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-18 - Regin
    DBTV-18
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    100 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    20...90 °C
    Hysteresis, temperature
    Maximum manual reset
    Reset function
    Manual
    Setpoint adjustment
    External
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-18U - Regin
    DBTV-18U
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    100 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    20...90 °C
    Hysteresis, temperature
    Maximum manual reset
    Reset function
    Manual
    Setpoint adjustment
    Internal
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-2U - Regin
    DBTV-2U
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    60 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    -30...30 °C
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Setpoint adjustment
    Internal
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-7 - Regin
    DBTV-7
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    75 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    0...60 °C
    Hysteresis, temperature
    2...20 K
    Reset function
    Automatic
    Setpoint adjustment
    External
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-8U - Regin
    DBTV-8U
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    75 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    0...60 °C
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Setpoint adjustment
    Internal
    Dimensions, external (WxHxD)
    72*70*108 mm
  • DBTV-17U - Regin
    DBTV-17U
    Sensor element
    Liquid-filled copper capillary
    Max. probe temperature
    100 °C
    Electrical contact
    SPDT microswitch
    Switching capacity
    15 (8) A, 24…250 V AC
    Setpoint value, temperature range
    20...90 °C
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Setpoint adjustment
    Internal
    Dimensions, external (WxHxD)
    72*70*108 mm

Specifications

Specifications for Immersion thermostat, IP65
Switching capacity 15 (8) A, 24…250 V AC
Setpoint value, temperature range -30...30 °C
Appliance class Class I
Protection class IP65
Ambient humidity (non-condensing) 10…90 % RH
Ambient temp -35…65 °C
Storage temp -40…70 °C
Storage humidity 10...95 % RH
Weight, incl. packaging 0.44 kg
Material, cover ABS
Material, base PC+ABS blend (Bayblend®)

Accessories