Navigate on this page
Articles
(8 st)-
DAS24
- Supply voltage
- 24 V AC/DC
- Torque
- 8 Nm
- Running time, actuator
- 30 s
- Damper shaft, round
- 10…20mm mm
- Damper shaft, square
- 10…20mm mm
- Damper shaft, min shaft length
- 50 mm
- Max damper size (area)
- 4 m²
- Frequency
- 50...60 Hz
- Power consumption in operation
- 3.9 W
- Power consumption in rest position
- 0.4 W
- Power consumption for wire sizing
- 6.5 VA
- Angle limitation
- 5...85° in 5° steps
-
DAS24S
- Supply voltage
- 24 V AC/DC
- Torque
- 8 Nm
- Running time, actuator
- 30 s
- Damper shaft, round
- 10…20mm mm
- Damper shaft, square
- 10…16mm mm
- Damper shaft, min shaft length
- 50 mm
- Max damper size (area)
- 2 m²
- Frequency
- 50...60 Hz
- Power consumption in operation
- 3.9 W
- Power consumption in rest position
- 0.4 W
- Power consumption for wire sizing
- 6.5 VA
- Angle limitation
- 5...85° in 5° steps
-
DAS230
- Supply voltage
- 230 V AC
- Torque
- 8 Nm
- Running time, actuator
- 30 s
- Damper shaft, round
- 10…20mm mm
- Damper shaft, square
- 10…20mm mm
- Damper shaft, min shaft length
- 50 mm
- Max damper size (area)
- 2 m²
- Frequency
- 50...60 Hz
- Power consumption in operation
- 4.8 W
- Power consumption in rest position
- 1.2 W
- Power consumption for wire sizing
- 6.5 VA
- Angle limitation
- 5...85° in 5° steps
-
DAS230S
- Supply voltage
- 230 V AC
- Torque
- 8 Nm
- Running time, actuator
- 30 s
- Damper shaft, round
- 10…20mm mm
- Damper shaft, square
- 10…20mm mm
- Damper shaft, min shaft length
- 50 mm
- Max damper size (area)
- 2 m²
- Frequency
- 50...60 Hz
- Power consumption in operation
- 4.8 W
- Power consumption in rest position
- 1.2 W
- Power consumption for wire sizing
- 6.5 VA
- Angle limitation
- 5...85° in 5° steps
-
DMS24
- Supply voltage
- 24 V AC/DC
- Torque
- 8 Nm
- Running time, actuator
- 30 s
- Damper shaft, round
- 10…20mm mm
- Damper shaft, square
- 10…20mm mm
- Damper shaft, min shaft length
- 50 mm
- Max damper size (area)
- 2 m²
- Frequency
- 50...60 Hz
- Power consumption in operation
- 4 W
- Power consumption in rest position
- 0.7 W
- Power consumption for wire sizing
- 6.5 VA
- Angle limitation
- 5...85° in 5° steps
-
DMS24S
- Supply voltage
- 24 V AC/DC
- Torque
- 8 Nm
- Running time, actuator
- 30 s
- Damper shaft, round
- 10…20mm mm
- Damper shaft, square
- 10…20mm mm
- Damper shaft, min shaft length
- 50 mm
- Max damper size (area)
- 2 m²
- Frequency
- 50...60 Hz
- Power consumption in operation
- 4 W
- Power consumption in rest position
- 0.7 W
- Power consumption for wire sizing
- 6.5 VA
-
DMS230
- Supply voltage
- 230 V AC
- Torque
- 8 Nm
- Running time, actuator
- 30 s
- Damper shaft, round
- 10…20mm mm
- Damper shaft, square
- 10…20mm mm
- Damper shaft, min shaft length
- 50 mm
- Max damper size (area)
- 2 m²
- Frequency
- 50...60 Hz
- Power consumption in operation
- 4.8 W
- Power consumption in rest position
- 1 W
- Power consumption for wire sizing
- 7.5 VA
- Angle limitation
- 5...85° in 5° steps
-
DMS230S
- Supply voltage
- 230 V AC
- Torque
- 8 Nm
- Running time, actuator
- 30 s
- Damper shaft, round
- 10…20mm mm
- Damper shaft, square
- 10…20mm mm
- Damper shaft, min shaft length
- 50 mm
- Max damper size (area)
- 2 m²
- Frequency
- 50...60 Hz
- Power consumption in operation
- 4.8 W
- Power consumption in rest position
- 1 W
- Power consumption for wire sizing
- 7.5 VA
- Angle limitation
- 5...85° in 5° steps
Specifications
Appliance class | Class III |
---|---|
Protection class | IP44 |
Protection class, additional information | IP54 with cable glands |
Ambient humidity (non-condensing) | 5…95 % RH |
Ambient temp | -20…50 °C |
Weight, incl. packaging | 1.2 kg |
Working angle, rotation | 90 ° |