Industrietechnik
Clamp-on sensor with cable
For surface temperature measurement. The sensors are compatible with a wide range of control systems, including Aquatrol, Johnson Controls, Satchwell, Trend, Cylon, Honeywell and many others. Contact our sales team to choose the model best suited to your application.
Articles
(12 st)-
SCC-PT100Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 1.5 m
- Measuring range, temp
- -30…150 °C
- Element type
- PT100
- Nominal resistance
- 100 Ω @0°C, Class B
-
SCC-PT1000Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 1.5 m
- Measuring range, temp
- -30…150 °C
- Element type
- PT1000
- Nominal resistance
- 1000 Ω @0°C, Class B
-
SCC-NTC1.8Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 1.5 m
- Measuring range, temp
- -30…120 °C
- Element type
- NTC1.8
- Nominal resistance
- 1800 Ω @25°C, Beta 3416
- Equivalent
- TAC
-
SCC-NTC2.2Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 1.5 m
- Measuring range, temp
- -30…150 °C
- Element type
- NTC2.2
- Nominal resistance
- 2252 Ω @25°C, Beta 3977
- Equivalent
- Johnson Controls
-
SCC-NTC10-01Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Media temp limits
- -30…150 °C
- Cable length
- 1.5 m
- Measuring range, temp
- -30…150 °C
- Element type
- NTC10-01
- Nominal resistance
- 10 kΩ @25°C, Beta 3977
- Equivalent
- Aquatrol - Johnson Controls - Satchwell - Trend - Cylon - Honeywell
-
SCC-NTC10-02-BR-J- Sensor Interface
- Passive
- Cable length
- 2 m
- Measuring range, temp
- -50…110 °C
- Element type
- NTC10-02
- Nominal resistance
- 10 kΩ @25°C, Beta 3435
- Equivalent
- Carel - Evco - Eliwell - AB Industrietechnik
-
SCC-NTC10-02Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 2 m
- Measuring range, temp
- -30…110 °C
- Element type
- NTC10-02
- Nominal resistance
- NTC 10k, 10 kΩ/25°C, Beta 3435
- Equivalent
- Carel - Evco - Eliwell - AB Industrietechnik
-
SCC-NTC10-03Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Media temp limits
- -30…150 °C
- Cable length
- 1.5 m
- Measuring range, temp
- -30…150 °C
- Element type
- NTC10-03
- Nominal resistance
- 10 kΩ @25°C, Beta 3695
- Equivalent
- Andover - Delta Controls - Siebe - York
-
SCC-NTC15-01Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 1.5 m
- Measuring range, temp
- 0…30 °C
- Element type
- NTC15
- Nominal resistance
- 15 kΩ @0°C
- Equivalent
- Regin - AB Industrietechnik
-
SCC-NI1000-01Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 1.5 m
- Measuring range, temp
- -30…150 °C
- Element type
- NI1000-01
- Nominal resistance
- 1000 Ω @0°C, TK5000
- Equivalent
- Siemens - Landis & Staefa
-
SCC-NI1000-02Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 1.5 m
- Measuring range, temp
- -30…150 °C
- Element type
- NI1000-02
- Nominal resistance
- 1000 Ω @0°C, TK6180
- Equivalent
- Sauter
-
SCC-NTC20Clamp-on sensor, including clamp (Ø 40 mm max.)- Sensor Interface
- Passive
- Cable length
- 1.5 m
- Measuring range, temp
- -30…150 °C
- Element type
- NTC20
- Nominal resistance
- 20kΩ (25°C)
- Equivalent
- Siemens - Landis & Staefa
Specifications
| Protection class | IP65 |
|---|---|
| Dimensions, external (WxHxD) | 10x7x35 mm |
| Media | Clamp-on sensor with cable for mounting on pipe |
| Material sensor | Nickel plated copper, Nickel-plated copper tube, Plastic rubber |
| Material cable | Silicone |
| Mounting: | Sul tubo con fascetta |
| Accessories, included | Metal clamp (diameters up to 40 mm), Metal clamp for diameters up to 40 mm. |
| Time constant | 13 s |
Software & documentation
Product sheet
Other documentation
Accessories