VFD3, 3-Way Control Valves with Internally Thread Union Connection, DN15–50
Valves, DN15-50, kvs 0.63-40, 20 mm stroke, intended for control of cold, hot and glycol-mixed water in heating, ventilation and domestic water systems. The valves are intended to be used together with Industrietechnik’s RVAN5 actuators. Valves with DN32-50 may also be used with RVAN10 if a larger actuating force is required.
Articles
(21 st)-
VFD315-0,63- Connection
- G 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN15
- Kvs
- 0.63 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD315-1,25- Connection
- G 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN15
- Kvs
- 1.25 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD315-1,0- Connection
- G 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN15
- Kvs
- 1 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD315-1,6- Connection
- G 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN15
- Kvs
- 1.6 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD315-2,5- Connection
- G 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN15
- Kvs
- 2.5 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD315-4,0- Connection
- G 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN15
- Kvs
- 4 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD320-5,0- Connection
- G 3/4" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN20
- Kvs
- 5 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD320-6,3- Connection
- G 3/4" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN20
- Kvs
- 6.3 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD320-4,0- Connection
- G 3/4" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN20
- Kvs
- 4 m³/h
- Max. diff. pressure
- 1600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD325-8,0- Connection
- G 1" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN25
- Kvs
- 8 m³/h
- Max. diff. pressure
- 1400 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD325-10- Connection
- G 1" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN25
- Kvs
- 10 m³/h
- Max. diff. pressure
- 1400 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD332-12,5- Connection
- G 1 1/4" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN32
- Kvs
- 12.5 m³/h
- Max. diff. pressure
- 800 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
-
VFD325-6,3- Connection
- G 1" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN25
- Kvs
- 6.3 m³/h
- Max. diff. pressure
- 1400 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5
-
VFD332-16- Connection
- G 1 1/4" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN32
- Kvs
- 16 m³/h
- Max. diff. pressure
- 800 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
-
VFD340-20- Connection
- G 1 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN40
- Kvs
- 20 m³/h
- Max. diff. pressure
- 600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
-
VFD340-25- Connection
- G 1 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN40
- Kvs
- 25 m³/h
- Max. diff. pressure
- 600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
-
VFD332-10- Connection
- G 1 1/4" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN32
- Kvs
- 10 m³/h
- Max. diff. pressure
- 800 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
-
VFD350-31,5- Connection
- G 2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN50
- Kvs
- 31.5 m³/h
- Max. diff. pressure
- 400 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
-
VFD350-40- Connection
- G 2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN50
- Kvs
- 40 m³/h
- Max. diff. pressure
- 400 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
-
VFD340-16- Connection
- G 1 1/2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN40
- Kvs
- 16 m³/h
- Max. diff. pressure
- 600 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
-
VFD350-25- Connection
- G 2" (ISO 228-1) F with union
- Rangeability
- 100:1
- Stroke
- 20 mm
- Nominal diameter
- DN50
- Kvs
- 25 m³/h
- Max. diff. pressure
- 400 kPa
- Media temperature
- -5…150 °C
- Nipple
- DZR brass CW511L
- Cover lid
- DZR brass CW511L
- Valve Type
- 3-Way
- Actuator
- RVAN5, RVAN10
Specifications
| Application | Heating, Cooling, Ventilation |
|---|---|
| Pressure rating | PN16 |
| Connection types | BSP externally threaded according to ISO 228/1 |
| Flow characteristics | Equal percentage |
| Leakage | 0.1 % of Kvs () |
| Media | Hot water, Cold water, Glycol-mixed water (max. 50 % glycol) |
| Closing direction | When stem is pulled outward |
| Media temperature | -5…150 °C |
| Actuator connection | Standard for RVAN5.../RVAN10... actuators |
| Body | Gunmetal CC491K |
| Seat | Gunmetal CC491K |
| Plug | Gunmetal CC491K |
| Stem | Stainless steel 1.4305 |
| O-rings | EPDM |
| Stuffing box | Dezincification resistant brass CW511L |
| Nut | Galvanized malleable cast iron |
| Fitting seal | Novatec Premium 2, Nitrile bonded aramid fibre with graphite |
Software & documentation
Product sheet
Other documentation