Room-mounted temperature, humidity and CO₂ transmitter
TCO2AU transmitter series with automatic calibration sets new standards in CO₂ measurement for HVAC applications. It combines the measurement of the carbon dioxide level, temperature and relative humidity. Models with or without display are available.
Articles
(24 st)-
TCO2AUCO2 + °C + RH- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-PT100CO2 + RH + PT100, 100 Ohm (0°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 100 Ω @0°C, Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-PT1000CO2 + RH + PT1000, 1000 Ohm (0°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 1000 Ω @0°C, Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-NTC1.8CO2 + RH + NTC 1.8, 1800 Ohm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 1800 Ω @25°C, Beta 3416
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-NTC2.2CO2 + RH + NTC 2.2, 2252 Ohm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 2252 Ω @25°C, Beta 3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-NTC10-01CO2 + RH + NTC 10, 10 kOhm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 10 kΩ @25°C, Beta 3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-NTC10-02CO2 + RH + NTC 10, 10 kOhm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 10 kΩ @25°C, Beta 3435
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-NTC10-03CO2 + RH + NTC 10, 10 kOhm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 10 kΩ @25°C, Beta 3695
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-NTC20CO2 + RH + NTC 20, 20 kOhm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 20 kΩ @25°C, Beta 4262
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-NI1000-01CO2 + RH + Ni1000, 1000 Ohm (0°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 1000 Ω @0°C, TK5000
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-NI1000-02CO2 + Umidità + Ni1000- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 1000 Ω @0°C, TK6180
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-DCO2 + °C + RH- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-PT100CO2 + RH + PT100, 100 Ohm (0°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 100 Ω @0°C, Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-PT1000CO2 + RH + PT1000- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 1000 Ω @0°C, Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-NTC1.8CO2 + RH + NTC 1.8, 1800 Ohm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 1800 Ω @25°C, Beta 3416
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-NTC2.2CO2 + RH + NTC 2.2, 2252 Ohm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 2252 Ω @25°C, Beta 3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-NTC10-01CO2 + RH + NTC 10, 10 kOhm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 10 kΩ @25°C, Beta 3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-NTC10-02CO2 + RH + NTC 10, 10 kOhm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 10 kΩ @25°C, Beta 3435
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-NTC10-03CO2 + RH + NTC 10, 10 kOhm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 10 kΩ @25°C, Beta 3695
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-NTC20CO2 + RH + NTC 20, 20 kOhm (25°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 20 kΩ @25°C, Beta 4262
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-NI1000-01CO2 + RH + Ni1000, 1000 Ohm (0°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 1000 Ω @0°C, TK5000
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-D-NI1000-02CO2 + RH + Ni1000, 1000 Ohm (0°C)- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 1000 Ω @0°C, TK6180
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
-
TCO2AU-MCO2 + RH + °C- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Modbus
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-MCO2 + RH + °C- Mounting
- Room
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- Modbus
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
Specifications
| Power Supply | 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA |
|---|---|
| Appliance class | Class III |
| Protection class | IP30 |
| Ambient humidity (non-condensing) | 10…90 % RH |
| Storage temperature | -25…60 °C |
| Mounting | Room, Wall |
| Accuracy, temperature | 0.4 K, 0.3 K, 0.5 K, 0.2 K, 0.25 K |
| Terminal type | Screw Terminal |
| Terminal wire size | 1.5 mm² |
| Material, housing | Polycarbonate |
| Power consumption | < 2.5 W |
| Transformer power | 5 VA |
Software & documentation
Product sheet
Instructions
Other documentation