Industrietechnik
Wall humidity/temperature transmitter, IP65
Wall-mounted TUTE temperature and relative humidity transmitters are designed to accurately measure temperature in industrial HVAC applications. With reliable performance and easy installation, they provide enhanced system control. Featuring IP65 ingress protection, they are also ideal for outdoor applications, ensuring durability and reliability in challenging environments.
Articles
(20 st)-
TUTE0111- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE0121- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -30…50 °C
- Output temperature
- 0-10 V
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE0131- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- 0…100 °C
- Output temperature
- 0-10 V
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE0212- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- 0…50 °C
- Output temperature
- 4-20 mA (2 wire)
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE0222- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -30…50 °C
- Output temperature
- 4-20 mA (2 wire)
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 1.5
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE0232- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- 0…100 °C
- Output temperature
- 4-20 mA (2 wire)
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE1101- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE1102- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE1103- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 0-5 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE1301- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE1302- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE1401- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE1402- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE1501- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE1502- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE1601- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE1602- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- NTC
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
-
TUTE1701- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Sensor element, temperature
- PT1000
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE2101- Tube length
- 9.7 cm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
-
TUTE2102- Tube length
- 9.7 cm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Measuring range, temp
- -20…50 °C
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Min (11-(0,02xRL)) Vdc, max 30 Vdc
Specifications
| Mounting | Outdoor |
|---|---|
| Power Supply | 24VAC/DC (18...24 V AC 50Hz / 18...35 V DC), VA, 24VDC (... V DC) |
| Appliance class | Class III |
| Protection class | IP65 |
| Ambient humidity (non-condensing) | 10…95 % RH |
| Ambient temperature | -5…50 °C |
| Storage temperature | -20…70 °C |
| Mounting | Wall |
| Dimensions, external (WxHxD) | 75x75x36 mm |
| Weight, incl. packaging | 0.17 kg |
| Tube diameter | 12 mm |
| Accuracy, temperature | 1 K, 1.5 K, 2 K, 0.6 K, NTC 10K-02 B3435 K, NTC 1K8 B3416 K, 0.2 K, NTC 10K-01 B3977 K, NTC 10K-03 B3695 K, NTC 20K B4262 K, 0.3 K, PT100 Class B K |
| Measuring range, humidity | 0…100 % RH |
| Accuracy, humidity | ± 3% RH |
| Cable gland | M16x1,5 |
| Terminal type | Screw Terminal |
| Terminal wire size | 0.75 mm² |
| Material, housing | Polycarbonate (PC) |
| Material sealing | Grey |
| Power consumption | < 1 W |
| Power supply | 18...24 Vac / 18...35 Vdc, Min (11-(0,02xRL)) Vdc, max 30 Vdc |
Software & documentation
Product sheet
Instructions
Other documentation