Industrietechnik
Duct sensor with housing
Duct sensor for air temperature measurement in ventilation ducts. The sensors are compatible with a wide range of control systems, including Aquatrol, Johnson Controls, Satchwell, Trend, Cylon, Honeywell and many others. Contact our sales team to choose the model best suited to your application.
Articles
(11 st)-
STC-PT100-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- PT100
- Nominal resistance
- 100 Ω @0°C, Class B
-
STC-PT1000-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- PT1000
- Nominal resistance
- 1000 Ω @0°C, Class B
-
STC-PT1000/430-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x473x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…405 mm
- Measuring range, temp
- -30…70 °C
- Element type
- PT1000
- Nominal resistance
- 1000 Ω @0°C, Class B
-
STC-NTC1.8-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- NTC1.8
- Nominal resistance
- 1800 Ω @25°C, Beta 3416
- Equivalent
- TAC
-
STC-NTC2.2-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- NTC2.2
- Nominal resistance
- 2252 Ω @25°C, Beta 3977
- Equivalent
- Johnson Controls
-
STC-NTC10-01-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- NTC10-01
- Nominal resistance
- 10 kΩ @25°C, Beta 3977
-
STC-NTC10-02-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- NTC10-02
- Nominal resistance
- 10 kΩ @25°C, Beta 3435
- Equivalent
- Carel - Evco - Eliwell - AB Industrietechnik
-
STC-NTC10-03-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- NTC10-03
- Nominal resistance
- 10 kΩ @25°C, Beta 3695
- Equivalent
- Andover - Delta Controls - Siebe - York
-
STC-NTC20-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- NTC20
- Nominal resistance
- 20 kΩ @25°C, Beta 4262
- Equivalent
- Honeywell
-
STC-NI1000-01-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- NI1000-01
- Nominal resistance
- 1000 Ω @0°C, TK5000
- Equivalent
- Siemens - Landis & Staefa
-
STC-NI1000-02-YDuct sensor with housing- Mounting
- Duct
- Dimensions, external (WxHxD)
- 78x263x104 mm
- Media temp limits
- -30…70 °C
- Insertion length
- 60…205 mm
- Measuring range, temp
- -30…70 °C
- Element type
- NI1000-02
- Nominal resistance
- 1000 Ω @0°C, TK6180
- Equivalent
- Sauter
Specifications
| Protection class | IP65 |
|---|---|
| Mounting | Duct |
| Weight, incl. packaging | 0.19 kg |
| Tube diameter | 8 mm |
| Time constant | 16 s |
| Cable gland | M16x1,5 |
| Terminal type | Screw Terminal |
| Terminal wire size | 1.5 mm² |
| Detachable terminal | Yes |
| Material, housing | Polycarbonate (PC) |
| Material tube | Stainless steel, EN 1.4301 (AISI 304) |
Software & documentation
Product sheet
Other documentation