Navigate on this page
Articles
(14 st)-
TPGL1
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...100 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m three-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL1-420
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...100 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m two-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL2.5
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...250 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m three-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL2.5-420
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...250 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m two-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL6
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...600 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m three-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL6-420
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...600 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m two-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL10
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...1000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m three-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL10-420
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...1000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m two-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL16
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...1600 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m three-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL16-420
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...1600 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m two-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL25
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...2500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m three-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL25-420
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...2500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m two-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL40
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...4000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m three-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
-
TPGL40-420
- Dimensions, external (WxHxD)
- 24*55* mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...4000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale %
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale %
- Cabel
- 1.5 m two-wire
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
- Media temperature
- -15…+125°C
Specifications
Power Supply | 12...33 V DC / 24 V AC ±15 %,< 7 mA |
---|---|
Protection class | IP67 |
Ambient temp | -30…85 °C |
Storage temp | -50…100 °C |
Weight, incl. packaging | 0.9 kg |
Media | Liquids and gases |
(Well/Pressure) connection | G 1/4 " |
Pressure connection | Outside thread |
Dynamic response time | < 2 ms, 1 ms typically |
Material sealing | FPM |