Industrietechnik

Immersion sensor with housing, without well, R1/4"

Immersion sensor for temperature measurement of heating or cooling batteries in ventilation units. Probe in stainless steel without a well. The sensors are compatible with a wide range of control systems, including Aquatrol, Johnson Controls, Satchwell, Trend, Cylon, Honeywell and many others. Contact our sales team to choose the model best suited to your application.

Articles

(10 st)
  • SI-PT100-Y - Regin
    SI-PT100-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -20…120 °C
    Element type
    PT100
    Nominal resistance
    100 Ω @0°C, Class B
    Insertion length
    90 mm
  • SI-PT1000-Y - Regin
    SI-PT1000-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -20…120 °C
    Element type
    PT1000
    Nominal resistance
    1000 Ω @0°C, Class B
    Insertion length
    90 mm
  • SI-NTC1.8-Y - Regin
    SI-NTC1.8-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -20…120 °C
    Element type
    NTC1.8
    Nominal resistance
    1800 Ω @25°C, Beta 3416
    Equivalent
    TAC
    Insertion length
    90 mm
  • SI-NTC2.2-Y - Regin
    SI-NTC2.2-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -20…120 °C
    Element type
    NTC2.2
    Nominal resistance
    2252 Ω @25°C, Beta 3977
    Equivalent
    Johnson Controls
    Insertion length
    90 mm
  • SI-NTC10-01-Y - Regin
    SI-NTC10-01-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -20…120 °C
    Element type
    NTC10-01
    Nominal resistance
    10 kΩ @25°C, Beta 3977
    Equivalent
    Aquatrol - Johnson Controls - Satchwell - Trend - Cylon - Honeywell - Distech
    Insertion length
    90 mm
  • SI-NTC10-02-Y - Regin
    SI-NTC10-02-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -20…120 °C
    Element type
    NTC10-02
    Nominal resistance
    10 kΩ @25°C, Beta 3435
    Equivalent
    Carel - Evco - Eliwell - AB Industrietechnik
    Insertion length
    90 mm
  • SI-NTC10-03-Y - Regin
    SI-NTC10-03-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -20…120 °C
    Element type
    NTC10-03
    Nominal resistance
    10 kΩ @25°C, Beta 3695
    Equivalent
    Andover - Delta Controls - Siebe - York
    Insertion length
    90 mm
  • SI-NTC20-Y - Regin
    SI-NTC20-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -30…70 °C
    Element type
    NTC20
    Nominal resistance
    20 kΩ @25°C, Beta 4262
    Equivalent
    Honeywell
    Insertion length
    90 mm
  • SI-NI1000-01-Y - Regin
    SI-NI1000-01-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -20…120 °C
    Element type
    NI1000-01
    Nominal resistance
    1000 Ω @0°C, TK5000
    Equivalent
    Siemens - Landis & Staefa
    Insertion length
    90 mm
  • SI-NI1000-02-Y - Regin
    SI-NI1000-02-Y
    Immersion sensor
    Media temp limits
    -20…120 °C
    Measuring range, temp
    -30…70 °C
    Element type
    NI1000-02
    Nominal resistance
    1000 Ω @0°C, TK6180
    Equivalent
    Sauter
    Insertion length
    90 mm

Specifications

Specifications for Immersion sensor with housing, without well, R1/4"
Mounting Immersion
Protection class IP65
Dimensions, external (WxHxD) 78x158x104 mm, 78x263x104 mm
Weight, incl. packaging 0.16 kg, 0.19 kg
Tube diameter 5 mm
Mounting Duct
Time constant 4 s
Pressure rating immersion PN16
(Well/Pressure) connection R 1/4 "
Cable gland M16x1,5
Terminal type Screw Terminal
Detachable terminal Yes
Terminal wire size 1.5 mm²
Material, housing Polycarbonate (PC)
Material tube Stainless steel, EN 1.4301 (AISI 304)